TIP REMOVER
A urethane gel that lifts dirt and oil from gloved fingertips when you squeeze it. Wash it and use it again.

Features
When it helps
- You want an easier clean than a roller.
- You want to lift fingertip dust without stopping the line.
- You want to show contamination control in an audit.

Follows the fingertip
The hollow gel wraps the fingertip and is easy to squeeze.
Removal test
Method: ATP (+AMP) swab
Instrument: Kikkoman Biochemifa Lumitester
A rubber glove with dust on the fingertips is compared with the same glove after TIP REMOVER.
This is an in-house check. The same result may not always occur.
| TIP REMOVER | Semiconductive |
|---|---|
| 80% or more | 85% or more |

Rinse and use again
Rinse and rub gently. Stickiness returns when it dries. A sanitizing cleaner keeps it clean longer.

No silicone, no plasticizer
Nothing from the gel, and no adhesive, is left on the glove.

Walls and ceilings too
No adhesive is added. Its own tack holds it on a bench, a wall, or a ceiling.
Repeated use and dust returning from TIP REMOVER
Procedure:
1. Dust a rubber glove.
2. Squeeze TIP REMOVER and remove the dust.
3. Dust the rubber glove again.
4. Repeat 1 to 3, and check how many times it can be used and whether dust returns.
This is an in-house check. The same result may not always occur.
Method: ATP (+AMP) swab
Instrument: Kikkoman Biochemifa Lumitester
Uses / Glove cleanliness
The baseline is a hand-soap wash (cleanliness 1490, the red line).
After 100 continuous uses, dust did not return to the glove, and the glove was cleaner than the baseline.
Uses / Glove cleanliness
The baseline is a hand-soap wash (cleanliness 1490, the red line).
After 120 continuous uses, the semiconductive type did not return dust to the glove, and the glove was cleaner than the baseline.
Cleanliness after rinsing
Procedure: compare an unused TIP REMOVER with one rinsed and dried after use.
This is an in-house check. The same result may not always occur.
Method: ATP (+AMP) swab
Instrument: Kikkoman Biochemifa Lumitester
15
Before
2,833
After use
17
After rinse
32
Before
2,518
After use
17
After rinse
Cleanliness before use and after rinsing was almost the same.
Video
Structure
The hollow urethane gel follows the finger and is easy to grip. It is 50 mm high and 80 mm wide at the base.

Polyurethane

Semiconductive polyurethane
Where it is used
It takes dust off gloves. The gel holds, so it can sit on a bench, a wall, or a ceiling.

On a wall

On a ceiling
Where to place it
The layout below keeps it on the route where people pass.

- Clean area
- Semi-clean area
- Contaminated area
Dust catcherInside the air shower
HAIMEN MATBefore entering the workroom
Body roller / D-QuickBefore entering the workroom
STEPMATWhere dirt falls, and at doors between zones of different cleanliness
TIP REMOVERWork where dirt must not reach the product
Lift matA doorway that indoor vehicles pass through
How to use
Cleaning
- Squeeze it with a gloved hand.
- Rinse and rub gently. Stickiness returns when it dries.
- A sanitizing cleaner helps it stay clean longer.

Customer notes
Fingertip dust comes off easily
The hollow shape is easy to squeeze with one hand during work. Rinsing and reusing it cut the cost of consumables.
No worry about adhesive transfer
A peel-off roller raised concern that adhesive would transfer. TIP REMOVER does not use adhesive.
Lineup

TIP REMOVER
| Code | Hardness | Size | Color |
|---|---|---|---|
| TR00-14001 | Asker C30 | Base Φ80 × height 50 | Blue green |

Semiconductive
| Code | Hardness | Size | Color | Surface resistance |
|---|---|---|---|---|
| TR01-14002 | Asker C30 | Base Φ80 × height 50 | Black | 10⁹ Ω |
Questions
- How do you clean it?
- Rinse it and rub gently with the palm.

Contact
If you have a question or would like to talk, please get in touch.
