Flux cleaner

A flux cleaner for reflow parts and carrier pallets. Use it for spray cleaning or tank cleaning after dilution.

Back to products

Flux cleaner

How to use

Spray cleaning

  • Dilution

    Mix chemical and water at 1:2, or about 33%.

  • Use

    For reflow parts inside the machine that cannot be removed.

  • Steps

    Spray and wait about 8–10 minutes. No residue is left in the machine.

Tank-based cleaning

  • Dilution

    Mix chemical and water at 1:3, or about 25%.

  • Use

    For reflow parts that can be removed and cleaned in a tank.

  • Steps

    Soak and wait about 15–30 minutes. Use about 45–50°C.

Results

  • Reflow parts

    Before
    Before
    After
    After
  • Carrier pallets

    Before
    Before
    After
    After

Contact

If you have a question or would like to talk, please get in touch.

FIDEA Corporation (Thailand) Co., Ltd.

+66 (0) 2-714-7621Sales@fidea.co.th

Contact form